SC417/SC427
4
Electrical Characteristics (continued)
Parameter
Conditions
Min Typ Max Units
Input Supplies (continued)
V5V Supply Current
ENL , EN/PSV = 0V
3
7 糀
SC417, EN/PSV = V5V, no load (f
SW
= 25kHz),
V
FB
> 500mV
(2)
2
mA
SC427, EN/PSV = V5V, no load, V
FB
> 500mV
(2)
0.7
f
SW
= 250kHz, EN/PSV = floating , no load
(2)
10
FB On-Time Threshold
Static V
IN
and load, 0 to +85 癈
0.496 0.500 0.504 V
Static V
IN
and load, -40 to +85 癈
0.495
0.505 V
Frequency Range
Continuous mode operation
200
1000
kHz
Minimum f
SW
, (SC417 only), EN/PSV = V5V, no load
25
Bootstrap Switch Resistance
10
&
Timing
On-Time
Continuous mode operation,
V
IN
= 15V, V
OUT
= 5V, f
SW
= 300kHz, R
TON
= 133k&
999 1110 1220 ns
Minimum On-Time
(2)
80
ns
Minimum Off-Time
(2)
250
ns
Soft-Start
Soft-Start Ramp Time
(2)
850
約
Analog Inputs/Outputs
VOUT Input Resistance
500
k&
Current Sense
Zero-Crossing Detector Threshold
LX - PGND
-3 0 +3 mV
Power Good
Power Good Threshold
Upper limit, V
FB
> internal 500mV reference
+20
%
Lower limit, V
FB
< internal 500mV reference
-10
%
Start-Up Delay Time
2
ms
Fault (noise immunity) Delay Time
(2)
5
祍
Leakage
1 礎
Power Good On-Resistance
10
&